Patient Monitor
8" patient Monitor
MD908
Features Specifications Download Catalogue

ECG
Lead Mode                    5 Leads ( R, L, F, N, C or RA, LA, LL, RL, V)
Lead selection              I, II, III, avR, avL, avF, V,
Waveform                       2 ch
Lead mode                    3 Leads ( R, L, F or RA, LA, LL)
Lead selection              I, II, III,
Waveform                      1 ch
Gain                              ´2.5mm/mV, ´5.0mm/mV, ´10mm/mV, ´20mm/mV
HR and Alarm       
Range    
Adult                        15 ~ 300 bpm
Neo/Ped                15 ~ 350 bpm
Accuracy              ㊣1% or ㊣1bpm, which great
Resolution             1 bpm
Sensitivity             > 200 uV P-P
Differential Input Impedance > 5 M次
CMRR
Monitor                    > 105 dB
Operation               > 105 dB
Diagnosis              > 85 dB
Electrode offset potential        ㊣300mV
Leakage Current                         < 10 uA
Baseline Recovery                      < 3 s  After Defi.
ECG Signal Range                      ㊣8 mV (Vp-p) 
Bandwidth  
Surgery                 1 ~ 15 Hz
Monitor                 0.5 ~ 35 Hz
Diagnostic           0.05 ~ 100 Hz
Calibration Signal                        1 mV (Vp-p),  ㊣5%  Accuracy
ST Segment Monitoring Range           
Measure and Alarm       -2.0 ~ +2.0 mV
ARR Detecting      
Type                             ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC
Alarm                           Available
Review                        Available

RESPARATION
Method                                                Impedance between R-F(RA-LL)
Differential Input Impedance         >2.5 M次
Measuring Impedance Range:      0.3~5.0次
Base line Impedance Range:        0 每 2.5 K次
Bandwidth                                          0.3 ~ 2.5 Hz
Resp. Rate
Measuring and Alarm Range      Adult              0 ~ 120 rpm
                                                           Neo/Ped         0 ~ 150 rpm
Resolution                    1 rpm
Accuracy                       ㊣2 rpm
Apean Alarm                10 ~ 40 S

NIBP
Method                                      Oscillometric
Mode                                         Manual, Auto, STAT
Measuring Interval in AUTO Mode 1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240, 480 Min
Measuring Period in STAT Mode   5 Min
Pulse Rate Range                       40 ~ 240 bpm
Alarm Type                      SYS, DIA, MEAN
Measuring and alarm Range                Adult Mode
SYS             40 ~ 270 mmHg
DIA              10 ~ 215 mmHg
MEAN           20 ~ 235 mmHg
                     Pediatric Mode
SYS             40 ~ 200 mmHg
DIA               10 ~ 150 mmHg
                     MEAN        20 ~ 165 mmHg
                     Neonatal Mode
SYS             40 ~ 135 mmHg
DIA              10 ~ 100 mmHg
MEAN           20 ~ 110 mmHg
Resolution     
Pressure                      1mmHg

Accuracy Pressure
Maximum Mean error                     ㊣5mmHg
Maximum Standard deviation       ㊣8mmHg
Overpressure Protection
Adult Mode                  297㊣3 mmHg
Pediatric Mode        240㊣3 mmHg
Neonatal Mode        147㊣3 mmHg


SpO2
Measuring Range                        0 ~ 100 %
Alarm Range                                 0 ~ 100 %
Resolution                                     1 %
Accuracy                     70% ~ 100%  ㊣2 %
                                       0%  ~  69% unspecified
Actualization interval                   about 1Sec.
Alarm Delay                               10 Sec.
Pulse Rate
Measuring and Alarm Range
0~254bpm
Resolution                           1bpm
Accuracy                                   ㊣2bpm
Alarm Delay                        10 Sec.
 
MASIMO Specification:
Range
Saturation(%SpO2)                            1%~100%
Pulse Rate(bmp)                                25~240
Accuracy
Saturation(%SpO2) ㄜ During No Motion Conditions*
Adults                                        70%ㄜ100ㄔ㊣2digits
0%-69% unspecified
Neonates                                          70%ㄜ100%㊣2digits
Saturation(%SpO2) ㄜ During Motion Conditions**
Adults                                        70%ㄜ100ㄔ㊣3digits
0%-69% unspecified
Neonates                                          70%ㄜ100%㊣3digits
Pulse(bpm) ㄜ During No Motion Condition 25 to 240 ㊣ 3digits
Pulse(bpm) ㄜ During Motion Condition 25 to 240 ㊣ 5digits
Resolution
Saturation(%SpO2)                            1%


TEMPERATURE
Channel                                     2
Measuring and Alarm Range        0 ~ 50 ∼C
Resolution                                  0.1∼C
Accuracy                                          ㊣0.1∼C
Actualization interval                   about 1 Sec.
Average Time Constant                < 10 Sec.



EtCO2 , IBP , Recorder