Patient Monitor
¡¡

3.5" patient Monitor

¡¡

Features Specifications Download Catalogue

ECG specification

Lead

Input:

5-lead cable: RA; LA; RL; LL; C

Lead method: I; II; III; avR; avL; avF; V; CAL(calibration)

No. of channels: 7 channels

Gain: X0.5; X1; X2; X4; Automatic

HR

Adult measurement & alarming range: 15-300bpm

Newborn/ infant measurement & alarming range: 15-350bpm

Precision: ¡À1%

Resolution: 1bpm

Sensitivity: >200uV (peak-to-peak value)

Differential input impedance: over 5M ohm

CMR: Non-filtering mode >60dB

Filtering mode >80dB

Electrode polarized voltage range: ¡À300mV

Leakage current: less than 10uA

Protection: Electric isolation: 4000VAC/50Hz voltage

Defibrillation/ electric knife resistant, Grid/ EMG resistant

Baseline recovery time: After defibrillation <5 seconds (under Filtering mode)

Scaling signal: 1mV (peak-to-peak value)

Accuracy: ¡À3%

Frequency response (bandwidth):

Filtering mode: 0.5-25Hz

Non-filtering mode: 0.05-75Hz

Alarm: Voice-alarm dual alarms, with review function

Pacing: Pacemaker works only after capturing pacing

RESP specification

Method: RA-LL impedance method

RR measurement & alarming range:

Adult: 7-100rpm

Infant/ newborn: 7-100rpm

Resolution: 1rpm

Precision: ¡À2rpm

Differential input impedance: Over 2.5M ohm, RA-LL lead

Choke alarm: 10-40 seconds

NIBP specification

Measurement method: Automatic vibration

Work mode: Manual / Automatic/ Continuous;

Unit: mmHg;

Measurement range:

Adult: Systolic pressure 25-255mmHg

Diastolic pressure 10-220mmHg

Average pressure 20-235mmHg

Overpressure protection: dual protection

(1) 300mmHg

(2) 300¡À10%mmHg

Infant: Systolic pressure 20-180mmHg

Diastolic pressure 10-150mmHg

Average pressure 10-160mmHg

Overpressure protection: 180mmHg

Newborn: Systolic pressure 20-120mmHg

Diastolic pressure 5-100mmHg

Average pressure 10-110mmHg

Overpressure protection: dual protection

(1) 120 mmHg

(2) 120¡À10%mmHg

Resolution: 1mmHg

Precision: Tolerance < ¡À5mmHg, less than 8 mmHg

PR range: 40-240bpm

Alarm: Systolic/diastolic/average pressure: 0-300mmHg

SpO2 specification

Measurement & alarm range: 0-100%

Resolution: 1%

Precision: ¡À2% (70-100%); ¡À3%(60-70%)

(no statement (below 60%))

PR and alarm range: 0-254bpm

Resolution: 1bpm

Precision: ¡À1%

TEMP specification

Measurement & alarm range: 0-45¡ãC

Resolution: 0.1¡ãC

Precision: ¡À0.1¡ãC (circuit precision)

¡À0.2¡ãC (including TEMP sensor)

No. of channels: 1 channel, displaying 1 TEMP value

Power supply socket

Simulated signal output (1V & 5V amplitude optional, tolerance

<20%), output impedance 50ohm, signal delay <30ms

Battery: Chargeable, maximally for 1 hour use

TREND time: 1-72 hours

Recorder: Not provided by default